Door Installation Procedures
WALL POSITIONING (90° / 180°)
Betcrete Frames are suitable to
be positioned centre, inside or outside flush. It is recommended
that all external frames (opening out) be installed with door stops.

|

|
| Doorframe
position for a 90° Opening |
Doorframe
position for a 180° Opening |
SETTING UP PROCEDURE
|
|
A. FOR CAST IN ONE
8/2100 & 9/2100 & 13/2100 DOORFRAMES
|
- Ensure doorframe is in position (
Square and plump)
- Use Temporary timber supports
(supplied by Builder) and (refundable) Templates (as per
illustration)
- After brickwork is dry, remove
support and templates.
|
 |
|
B. FOR 17/2100
DOORFRAMES
|
-
Place applicable (Refundable) jig
within door frame. Clamp styles onto jig supplied
with g-clamps.
-
Adjust T-stay until plumb in all
directions.
-
Place transom (top piece) in
position and align inside rebate on door side.
-
Bend out lugs and proceed with
brickwork, filling mortar between frame and
brickwork.
-
The reusable jigs must be kept in
position until brickwork above the transom is dry.
|
 |
|
ALLOW FOR SCREET BY
WEDGING FROM OUR JIG |
CROSS SECTION DIAGRAM

|